Anhui Wanyi Science and Technology Co., Ltd.

To build an enterprise with strong international competitiveness in the field of analytical and testing instruments and life and health.

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Liquid Chromatography Instrument /

Flow to Needle High Performance Liquid Chromatography Instrument With Binary Pump

Contact Now
Anhui Wanyi Science and Technology Co., Ltd.
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:MsAnnie
Contact Now

Flow to Needle High Performance Liquid Chromatography Instrument With Binary Pump

Ask Latest Price
Video Channel
Brand Name :Wayeal
Model Number :LC3400
Certification :ISO, CE
Place of Origin :Anhui, China
MOQ :1
Price :Negotiation
Payment Terms :L/C, T/T
Supply Ability :30 Pieces Per Month
Delivery Time :30 days
Packaging Details :Wooden Case
Product Name :Liquid Chromatography Instruments
Number of arrays :1024
Warranty :1 Year
Power supply :220V 50HZ
Ambient Temperature :10-40℃
Light Source :Deuterium (D2) lamp
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Techncial Data of LC3400 High Performance Liquid Chromatography Instrument

Product Name

LC3400 Liquid Chromatography Instrument

Maximum Operating Pressure

62MPa/75MPa

Flow Rate Setting Range

0.0000~12.0000mL/min

Flow Rate Setting Increment

0.0001mL/min

Gradient Error

≤ 0.75%

Gradient Stability

0.2% RSD (5% to 95%, 0.2 to 2.0mL/min)

Flow Rate Setting Value Error

±0.20%

Flow Rate Stability

≤0.075% RSD

Autosampler

Injection Volume

100μL, 200μL, 500μL, 1000μL, 1500μL, 2000μL

Repeatability

<0.3%RSD (2μL~Max),

<1.0%RSD (0.1μL~1.9μL);

Linear Correlation Coefficient

>0.9999

Number of Sample Position

108 (2*54, 2mL), 96-well plates

Temperature Setting Range

4.0~40.0℃ (optional refrigeration)

Temperature Setting Value Error

±0.5℃ (optional refrigeration);

Temperature Stability

±1℃ (optional refrigeration)

Column Oven

Temperature Setting Range

4℃-90℃

Temperature Stability

±0.03℃/h

Temperature Setting Value Error

±0.1℃

UV Detector

Baseline Noise

≤8.0×10-6 Au (1mL/min, methanol, C18)

Baseline Drift

≤1.0×10-4 Au/h (1mL/min, methanol, C18)

Minimum Test Concentration

≤5×10-9 g/mL (naphthalene/methanol)

Spectral Range

188-900nm

Wavelength Error

≤ ±1nm

Wavelength Repeatability

≤ ±0.1nm

Linear Range

≥1×104 or 2.5Au


Performance of High Performance Liquid Chromatography Instrument
1. High-precision ultra-high-pressure infusion unit

2. Low system diffusion volume and optimized flow path

3. Needle-in-flow autosampler with ultra-low injection cycle time

4. Extremely low cross-contamination

5. Active preheat function, fast warming rate