Description of Ion Chromatography Instrument:
Ion chromatography is characterized by rapidity, sensitivity and good selectivity, especially in the detection of anions, which has the advantages of other methods. Therefore, it is widely used in the chemical industry, pharmaceutical industry, environmental protection, sanitary and epidemic prevention, semiconductor manufacturing, etc., and has been listed as a standard measurement method in some fields.
Technical Parameters of Ion Chromatography Instrument:
Precise PEEK Quaternary Pump Ion Chromatography System with Inline Eluent Generator | |
---|---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10μL~400μL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500μL, options 250μL, 100μL, 2500μL |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3Mpa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005μg/mL |
Min Detection Concentration (Li) | ≤0.0002μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Applications of Ion Chromatography Instrument:
The Ion Chromatography Instrument is a widely used laboratory tool for analyzing and separating ions in complex mixtures. It is often used in environmental, pharmaceutical, and chemical industries.
Here are some specific product application occasions and scenarios: